Vue de la page 31
TANDBERG 3G Gateway Data port Command Interface User Guide
4.2.4. Debug Commands
Command: Desription:
Syslog
Enables a real-time log of Bonding, H.221 and H324m, ISDN, RTSP, IVider, and IVider Engine activity.
Note! H323 and SIP logging is presented using the following command:
tsh –a H323 (SIP).
Note! Logging via the serial port is limited by the speed of the serial port, which might result in loss of
logging data. Therefore, it is advised to use Telnet instead.
Syslog <Level> <Mask> <Volume>
<level> = log level, 0-99, 0 turns off log
<mask> = bitmask (default=65535):
Mask: With this Mask the logging of different components can be turned on. The
mask has to be used as a bit mask.
H324m: 1 (0x0001)
ISDN: 4 (0x0004)
RTSP: 8 (0x0008)
IVider: 16 (0x0010)
Engine: 64 (0x0040)
FileStreamer: 128 (0x0080)
ContentStreamer: 256 (0x0100)
Transcoder: 512 (0x0200)
Mux: 1024 (0x0400)
Cuil: 2048 (0x0800)
<volume> = message volume mask (default=0):
Medium: 1 (0x01)
High: 2 (0x02)
Show timestamp: 4 (0x04)
Show IP address: 8 (0x08)
Show Process: 16 (0x10)
Show Session ID: 32 (0x20)
For instance to view the logging of the H324m, Transcoder and IVider components, the mask value equals 1
+ 512 + 32 = 545